Configuring Light Source

Configure test module as test light source

1. Plug module into ControlLogix rack

2. Set desired light power. Switch up for hi power output. Switch down

for low power output.

Configure Ultra3000

TM

drive as test light source

1. Set baudrate rotary switch to the 9:00 position to enable continuous

light output mode.

2. Power up the drive

The drive is outputting in continuous light mode at maximum output power.

Configure Kinetix

TM

family drive as test light source

1. Set DIP switch 1 to proper position to enable high power output.

(See drive user manual for proper position).

2. Connect a computer to the Drive via a serial port and anaconda.

3. Use drive explorer software to set IDN701 to a value of 91 to enable

continuous light output mode.

The drive remains in this mode until power is cycled.

Measurement using general purpose LED source.