Fiber optic cable specifications, Plastic fiber optic cable mechanical limits – Rockwell Automation 2090-xxx Fiber Optic Cable Installation and Handling Instructions User Manual

Page 25

Advertising
background image

Fiber Optic Cable Installation and Handling Instructions 25

Publication 2090-IN010C-EN-P – April 2005

Fiber Optic Cable Specifications

Hard Clad Silica Glass Fiber Optic Cable Mechanical Limits

*Highly susceptible to fracture under twisting load.

Plastic Fiber Optic Cable Mechanical Limits

Catalog
Number

Length
meters,
(inches)

Long Term
Bend
Radius

No Load
mm (in.)

Maximum
Tensile
Load
Newtons
(Lbs.)

Impact

Twist
(times)

2090-SCVG50-0

50, (1970)

30 (1.2)

<98 (22)

490 N/5 cm

Avoid*

2090-SCVG100-0

100, (3937)

30 (1.2)

<98 (22)

490 N/5 cm

Avoid*

2090-SCVG150-0

150, (5905)

30 (1.2)

<98 (22)

490 N/5 cm

Avoid*

2090-SCVG200-0

200, (7874)

30 (1.2)

<98 (22)

490 N/5 cm

Avoid*

Catalog
Number

Length
meters,
(inches)

Long Term
Bend
Radius

No Load
mm (in.)

Maximum
Tensile
Load
Newtons
(Lbs.)

Impact

Twist
(times)

2090-SCEP0-1

0.1, (4)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP0-3

0.3, (12)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP0-9

0.9, (35)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP1-0

1, (39)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP3-0

3, (118)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP5-0

5, (197)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP8-0

8, (315)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP10-0

10, (394)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP15-0

15, (591)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP20-0

20, (787)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

2090-SCEP25-0

25, (984)

25.4 (1.0)

< 70 (15)

0.4 N·m

5

Advertising