Fiber Optic Cable Installation and Handling Instructions 9

Publication 2090-IN010C-EN-P – April 2005

3. Verify that optometer is set to measure appropriate wavelength and

attenuation in dB.

Figure 8 Attenuation Measurement

4. Securely connect test cable between source and optometer.

5. Use the dB value on the optometer to verify that the cable under test

is within specification listed in the table for that specific catalog
number.

6. Reverse the cable and test again starting at step 2.

Cable Attenuation Measurement with Bulkhead Connector

1. Inspect ends of cable for proper termination. Clean ends of fiber.

2. Turn on light Source

3. Securely connect appropriate reference cable corresponding to the

type of cable to be tested.

• POF reference cable used for testing POF cable
• HCS reference cable used for testing HCS cable

4. Securely connect bulkhead connector to reference cable.

5. Securely connect test cable between bulkhead connector and

optometer.

Figure 9 Attenuation Measurement with Bulkhead Connector

LED Light Source
650nM nominal

Optometer measuring
loss in dB

Test Cable

LED Light
Source
650nM
nominal

Optometer measuring
loss in dB

Test Cable

1 meter
reference
cable

Coupler
2090-s-blhd

Advertising