Kinetix 300 Drive Power-Wiring Requirements

Cat. No.

Description

Terminals

Recommended
Wire Size
mm

2

(AWG)

Strip
Length
mm (in.)

Torque
Value
N•m (lb•in)

Pin

Signal

2097-V31PR0
2097-V32PR0
2097-V32PR2
2097-V33PR1
2097-V33PR3
2097-V34PR3
2097-V34PR5
2097-V34PR6

Mains input power

L3
L2
L1
PE

2.5 (14)

7 (0.28)

0.5 (4.5)

2097-V32PR4
2097-V33PR5

4.0 (12)

2097-V31PR2
2097-V33PR6

6.0 (10)

0.56…0.79
(5.0…7.0)

2097-V31PR0
2097-V32PR0
2097-V32PR2
2097-V32PR4
2097-V33PR1
2097-V33PR3
2097-V33PR5
2097-V34PR3
2097-V34PR5
2097-V34PR6
2097-V31PR2

Motor power

PE
W
V
U

2.5 (14)

7 (0.28)

0.5 (4.5)

2097-V33PR6

4.0 (12)

7 (0.28)

0.5 (4.5)

2097-V31PR0
2097-V32PR0
2097-V32PR2
2097-V32PR4
2097-V33PR1
2097-V33PR3
2097-V33PR5
2097-V34PR3
2097-V34PR5
2097-V34PR6
2097-V31PR2

Shunt resistor and DC bus

(1)

+
+
SH

2.5 (14)

7 (0.28)

0.5 (4.5)

2097-V33PR6

4.0 (12)

7 (0.28)

0.5 (4.5)

2097-V3

xPRx

Control back-up power

+24V DC
Return

1.5 (16)

6 (0.25)

0.5 (4.5)

2097-V3

xPRx

Safe torque-off

STO-1

(2)

STO-2

(2)

STO-3
STO-4
STO-5
STO-6

+24V DC Control

Control COM
Safety Status
Safety Input 1
Safety COM
Safety Input 2

(1)

Use only for shunt on.

(2)

Use only for bypassing the STO circuit.

Advertising