Install the Kinetix 300 Drive

These procedures assume you have prepared your panel, and understand how to bond your
system. For installation instructions regarding equipment and accessories not included here, refer
to the instructions that came with those products

Mount the Kinetix 300 Drive

Follow these steps to mount the drive.

1. Observe these clearance requirements when mounting the drive to the panel.

SHOCK HAZARD: To avoid hazard of electrical shock, perform all mounting and wiring of the
Kinetix 300 drive prior to applying power. Once power is applied, connector terminals can have
voltage present even when not in use.

ATTENTION: Plan the installation of your system so that you can perform all cutting, drilling,
tapping, and welding with the system removed from the enclosure. Because the system is
open-type construction, be careful to keep any metal debris from falling into it. Metal debris or
other foreign matter can become lodged in the circuitry and result in damage to components.

IMPORTANT

Mount the module in an upright position as shown. Do not mount the module on
its side.

Drive
Cat. No.

A
mm (in.)

2097-V31PR0

185 (7.29)

2097-V31PR2

2097-V32PR0

230 (9.04)

2097-V32PR2

2097-V32PR4

2097-V33PR1

185 (7.29)

(1)

(1)

If you are using an AC line filter, add 50
mm (2 in.).

2097-V33PR3

2097-V33PR5

2097-V33PR6

230 (9.04)

2097-V34PR3

185 (7.29)

(1)

2097-V34PR5

2097-V34PR6

230 (9.04)

A

Additional clearance and different hole patterns are required for side mount

and rear mount AC line filters. See the table and

step 2

for more details.

Additional clearance is required depending on the other accessories installed.
Additional clearance is required for the cable and wires connected to the top,

front, and bottom of the drive.

An additional 150 mm (6.0 in.) clearance is required when the drive is

mounted adjacent to noise sensitive equipment or clean wire ways.

Refer to

page 6

for Kinetix 300 drive dimensions.

25 mm (1.0 in.) Clearance

for Airflow and Installation

25 mm (1.0 in.) Clearance

for Airflow and Installation

3 mm (0.12 in.)

Side Clearance

3 mm (0.12 in.)
Side Clearance

Advertising