Connect ac power – Rockwell Automation VersaView 1200P Integrated Display Computers for Hazardous Locations User Manual
Page 17
 
VersaView 1200P Integrated Display Computers for Hazardous Locations 17
Publication 6183H-IN001E-EN-P - July 2007
Connect ac Power
A standard IEC 320 power cord provides power to the computer. The power supply 
input accepts 120/240V ac. The power supply is autoswitching.
Retainer Clip
ATTENTION
Select the power source carefully before connecting your computer.
The power cord must be connected to a terminal block and earth ground. 
Failure to follow this warning could result in severe electrical shock.
Installing the computers in a panel, enclosure or rack that is already 
connected to Earth ground will satisfy this requirement. Otherwise, 
connect your computer to Earth ground using a 1.31 mm
2
(16 AWG) or
larger external wire.
The ground wire should have green insulation with a yellow stripe for easy 
identification.
The power source selected must have its own disconnect. Do not connect 
the computer to a supply that is connected to the main electrical 
disconnect.
To prevent problems resulting from power surges or unexpected power 
failure, you should protect the outlet with its own fuses or circuit breakers, 
as well as an Uninterruptible Power Supply (UPS) system. 
Always shut down the operating system prior to removing power to 
minimize performance degradation and operating system failures.
1200P Only:
You may need to remove the ac retainer 
clip prior to installing the unit into a 
panel cut-out. Attach the clip after 
installing the unit.