European union directive compliance, Hazardous locations – Rockwell Automation VersaView 1200P Integrated Display Computers for Hazardous Locations User Manual

Page 3

Advertising
background image

VersaView 1200P Integrated Display Computers for Hazardous Locations 3

Publication 6183H-IN001E-EN-P - July 2007

European Union Directive Compliance

This computer meets the European Union Directive requirements when installed
within the European Union or EEA regions and has the CE mark. See http
://ab.com
for declarations of conformity, certificates, and other certification details.

Hazardous Locations

This equipment is suitable for:

• Class I, Zone 2, Group IIC.
• Class I, Division 2, Groups A, B, C, D.
• nonhazardous locations.

The dc powered touch-screen and non-display units are additionally suitable for
European Zone 2 applications as defined by EU Directive 94/9/CE (ATEX) as it
relates to Category 3 equipment intended for use in potentially explosive
atmospheres given in Annex II of this directive per EN60079-15:2003.

The units are rated:

• II 3G EEx nL IIC T4.
• 0 °C ≤ T

amb

≤ 50 °C.

• Certificate: DEMKO 06 ATEX 0627219 X.

ATTENTION

This product is intended to operate in an industrial or control room
environment, which utilizes some form of power isolation from the public
low-voltage mains. Some computer configurations may not comply with the EN
61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of
the European Union. Obtain permission from the local power authority before
connecting any computer configuration that draws more than 75 W of ac power
directly from the public mains.

ATTENTION

To comply with EN 55024, the Ethernet port LAN cable must be less than 30 m
(98.42 ft), and it must only be used indoors (not exit the building at any point).
All other I/O cables must be less than 3 m (9842 ft), and must only be used
indoors.

Advertising