Specifications

VersaView 1200P Integrated Display, 6183H-12FP, 6183H-12FPDC, 6183H-12NPDC,
6183H-2P, 6183H-2PDC, 6181H-2PXPHDC

Attribute

Value

Display description

Active Matrix Color TFT

Display size

12.1 inch

Display area, approx.

246 x 185 mm (9.7 x 7.3 in.)

Resolution

800 x 600, 256K Color

Response time

15 ms (typical)

Touchscreen (optional)

Projected capacitive

Mechanical Specifications

Attribute

Value

Weight

9.2 kg (21 lb)

Dimensions, overall (H x W x D), approx.

279 x 349 x 176 mm (11.0 x 13.75 x 6.93 in.)

Cutout dimensions (H x W), approx.

254 x 324 mm (10.0 x 12.76 in.)

Environmental Specifications

Attribute

Value

Temperature, operating

0…50 °C (32…122 °F)

Temperature, storage

-20…60 °C (-4…140 °F)

Relative humidity

10%…90% without condensation

Shock, operating

15 g (1/2 sine, 11ms)

Shock, non-operating

30 g (1/2 sine, 11ms)

Vibration, operating

1.5 g Peak (10…500Hz)

Vibration, non-operating

2 g Peak (10…500Hz)

Ratings

(1)

1200P
1200P (6181H/6183H Non-display)

(1)

When installed in enclosure with an equivalent rating.

NEMA Type 4, 12, IEC IP66

NEMA Type 1