Additional resources – Rockwell Automation VersaView 1200P Integrated Display Computers for Hazardous Locations User Manual

Page 22

Advertising
background image

22 VersaView 1200P Integrated Display Computers for Hazardous Locations

Publication 6183H-IN001E-EN-P - July 2007

Additional Resources

For additional information on the VersaView computers, refer to VersaView
Integrated Display Computers User Manual, publication 6
181P-UM001.

You can view or download publications at
http://literature.rockwellautomation.com. To order paper copies of technical
documentation, contact your local Rockwell Automation distributor or sales
representative.

Electrical Specifications

Attribute

Value

Input voltage, ac

90…264V ac, autoranging

Line frequency

47…63 Hz

Power consumption, ac

1200P
1200P (6181H/6183H Non-display)

150 VA (1.5 A @ 100V rms, 0.63 A @ 240 V rms)
140 VA (1.4 A @ 100V rms, 0.58 A @ 240 V rms)

Input voltage, dc

1200P
1200P (6181H/6183H Non-display)

18…32V dc

Power consumption, dc

1200P
1200P (6181H/6183H Non-display)

150 W
140 W

Certifications

Certification

(1)

Value

CE

Marked for all applicable directives
LVD (73/23/EEC)
EMC (89/336/EEC)

c-UL-us

UL 1604 recognized component, C-UL certified
UL-Listed Industrial Control Equipment for use in:

• Class I, Division 2, Groups A, B, C, D

• Class I, Zone 2, Group IIC

C-Tick

Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions

RoHS compliant

ATEX Zone 2

Applicable to dc powered touch-screen and non-display units only.

(1)

See http://ab.com for declarations of conformity, certificates, and other certification details.

Advertising