Wiring

The flying leads from the PDM drive is wired to the IF2 I/O Interface
to PDM board using the connector marked P1. The flying leads from
the external controller are wired to the connector marked P2 User.
Each set of connectors have 26 slots available and the wiring is a 1
to 1 set up. The IF2 I/O Interface should be mounted as close as
possible to the associated PDM. The wires from the PDM to the IF2
should be in the same railway and should not contain any power
leads.

Due to the positioning of the screws on the inside of the connectors,
it is easier to wire the connectors by first removing them and then
running the flying leads to the appropriate slots. It is recommended
that you remove only one connector at a time to avoid confusion
and reduce the possibility of error in matching the flying leads to the
correct slot on the connector.

Wiring Cable Flying Leads to the Plugs

To wire the cable leads to the plug:

1. Look at the plug to make sure the terminal is open. Figure 3

shows both an open and a closed terminal.

Figure 3 Terminal diagram

2.

Terminal Steps

If the terminals are:

Do this:

Not open

Go to step 3

Terminal open

Terminal closed

Clamping screws