Installing the AtomScan Scanner

This chapter provides the information needed to mount, wire, and correctly
aim the scanner. The following subjects are covered:

Environmental Issues

Aiming the scanner

Mounting Options

Package Sensor Orientation

Connecting the Scanner and Package Sensor

The AtomScan scanner is totally enclosed. It can tolerate light dust. However
it is not designed for use in harsh environments such as wash-down. If your
environment is harsh, consider using the NEMA Type 4 enclosed
2755-LD4x4 or 2755-LD8x4, where x is the focus code, A, B, C, or D.

Chapter 3 presented information necessary to select the correct scanner for
your application. The most important factors to consider in mounting the
scanner are:

make sure the bar code symbol passes within the scanner’s reading range

make sure the scan line will pass through all the symbol’s bars and the
quiet zones

mount the scanner so the scanning plane is 20

°

-30

°

off the perpendicular

Figure 4.1
Correct Setup of Scanner

20

_-30_

20

_-30_

Scanner between 20

_ and 30_

above or below the symbol

CAUTION:

Do not stare into laser beam, to avoid damage to your eyes.