Rockwell Automation 2755 Atomscan Bar Code Scanner User Manual

Page 33

Advertising
background image

Chapter 4

Installing the Scanner

4–6

Connecting the Package Sensor

Chapter 2 gives the information needed to select a retro-reflective
photo switch, and also lists the extension cable options.

The Adapter Module has a yellow stub cable with a Micro-Change
connector. The extension cable is connected to the Adapter Module’s
connector, and then to the connector on the sensor.

In case the sensor does not have a connector, the pinout is given in Table 4.A.
The package sensor must be able to operate using the +12V DC source
(pin 1) and not draw more than 100mA. The package detect sense line (pin 2)
must be able to sink 5mA at +12V DC.

Table 4.A
Pins Used on Package sensor Port

Package

Detect Port

Pin #

Pin Function

Wire Color

Face View Female

1

+12V DC

Brown

2 ➀

Package sensor Sense

White

3

Ground

Blue

4

No Connection

(internally pulled up to 12V DC)

Black

Triggers the decoder to start decoding. The trigger active LED on the decoder
lights when the package detect input is active.

If the laser is not ON, it could be because

the decoder has not been triggered, or

the symbol has already been decoded

The package sensor must go OFF then ON to trigger the decoder before a
new symbol can be decoded. Refer to the Enhanced Decoder user manual
(Publication No. 2755-833) for further details.

Advertising