Connecting equipment – Rockwell Automation 2755 Atomscan Bar Code Scanner User Manual

Page 31

Advertising
background image

Chapter 4

Installing the Scanner

4–4

The scanner is connected to the Enhanced Decoder through the Adapter
Module. The scanner cable is plugged into the Adapter Module, and then into
the scanner. Cables are available in 10-foot and 15-foot lengths, so mount the
decoder within that distance. Use the steps below as a guideline when
connecting equipment.

1. Make sure that power to the decoder is TURNED OFF.

!

ATTENTION: Do NOT connect or disconnect scanner when the
decoder has power on.

2. Connect the scanner to the Adapter Module (Catalog No. 2755-NC18)

using the RJ-45 connector of the 10-foot or 15-foot cable.

3. If a package sensor is used, connect it to the Micro-Change connector of

the Adapter Module.

4. Set up the decoder.

Connect the DB15 connector of the Adapter Module to the Scanner port
of the decoder.

Configure the decoder for your application if you have not already done
so. Refer to Decoder User Manual.

5. Refer to Chapter 5 on scanner operation.

Figure 4.4
A Possible Setup for a Scanning System

Monitor
(Optional)

Host

Package
sensor

Adapter

Decoder

Reflector

Scanner
Cable

Extension
Cable
(if needed)

Atom
Scan

Connecting Equipment

Advertising