Using the mounting plate – Rockwell Automation 2755 Atomscan Bar Code Scanner User Manual

Page 30

Advertising
background image

Chapter 4

Installing the Scanner

4–3

If you do not use the mounting plate, use the measurements given in
Figure 4.2 to locate centers of mounting holes. Drill four 5/32 inch
(4 mm) holes.

Note: If you use the mounting plate, refer to Figure 4.3. Mount the
scanner directly to the four inner holes on the plate, and use the four
perimeter holes for mounting the plate to its work location..

Using the Mounting Plate

The Mounting Plate (Catalog No. 2755-NM7) allows mounting on any flat
surface.

1.5 in

38.1 mm

3.3 in

83.82 mm

2.8 in

71.12 mm

2.1 in

53.34 mm

0.3 in

7.62 mm

Four countersunk holes,

for attaching plate to

scanner

Four 0.158 in (3.96 mm) diameter holes,

used to mount plate to any suitable surface

Thickness of Plate = 0.1 in (2.54 mm)

Figure 4.3
Installing With the Mounting Plate

Requires four #6-32 flat-
head 1/4 inch screws

Mounting Plate
(Catalog No. 2755-NM6)

Note: The scanner has four threaded
holes for mounting screws.

Advertising