RTD Input Equipment (T7432)


P D - 7 0 3 7 M a r - 0 6

25

points of failure and extend fault tolerance to include the
RTDs.

For additional safety considerations, please refer to the Safety
Considerations section of the Regent User’s Guide.

Specifications

Safetybus Power

1.8 load units

Number of Inputs

16, two, three, or four-wire
RTDs

RTD Input Types

American:
European:

100W Platinum
" = 0.00392 S/S/°C
" = 0.00385 S/S/°C

RTD Units

Degrees Centigrade or
degrees Fahrenheit

RTD Resolution

Tenths or units

RTD Temperature Range

Normal Operation:


Over-Range:


Under-Range:


-200

°

to +800

°

C

(-328

°

to +1470

°

F)

+801

°

to +883

°

C

(+1471

°

to +1622

°

F)

-242

°

to -201

°

C

(-404

°

to --329

°

F)

Input Resolution

14-bit, 1 part in 16,384

Response Time

2 seconds, typical

Linearization

Automatic

Calibration

Automatic

Maximum Lead Resistance


20 ohms

Current Source

1 mA (standard)

5 mA (optional)

Accuracy

T < 93

°

C (200

°

F)

T > 93

°

C (200

°

F)


+/- 0.55

°

C (1.0

°

F)

+/- 1.1

°

C (2.0

°

F)