Rockwell Automation GV3000/SE AC Drive 30-100HP, 230VAC V6.04 Hardware Ref, Install, Troubleshooting User Manual
Page 66

7-16
GV3000/SE 230 VAC 30-100 HP Drive, Hardware Reference Version 6.04
Parameters/Wiring Connections
The following parameter must be set:
P.000: Control Source
Terminal 22 On = Reset
The following parameters must be set:
P.000: Control Source
P.025: Stop Type
Terminal 23 Off = Stop
Terminal 24 On Transition = Start
Used with older Snubber Resistor Braking Kits that require a gate
turn-on signal from the drive (for example, the M/N 2DB2010
series).
Note that terminals 26 and 27 are not to be used with
Snubber Resistor Braking Kits M/N 2SR20400, 2SR20600,
2SR21200, 2SR21800, 2SR20300, and 2SR20450.
Table 7.8 – Wiring Signal and Control I/O to the Terminal Strip (Continued)
Terminal
Number
22
23
24
25
26
27
Description
Digital Input 3
(Reset)
Digital Input 2
(Stop)
Digital Input 1
(Start)
24 VDC Isolated Common
Snubber Resistor Braking
Control Signal
+24 VDC Isolated Common
Wiring the Reset Input
Wiring the Stop/Start Inputs
Wiring the Snubber Resistor
16
22
RESET
16
24
START
16
23
STOP