Step 2: Removing Covers
from the Power Structure

Moving Control Frame

Task

Description
Loosen the T8 Torx-head screws, which secure the Control Frame to
the drive enclosure (Remove screws on early frame 10 drives).

Swing the Control Frame out and away from the power structure.

A

B

B

Frame 10 Drive Shown

Frame 10 drives, from early production runs, have

holes instead of slots for these screws. You must

completely remove the screws from these drives in

order to swing-open the control frame.

or

A

A