PowerFlex® 700S and 700H Fan Inverter Upgrade Kit (Frame 10-11)

Step 4: Removing Inverter
Assemblies

Left-hand and Right-hand Inverter Assemblies

Task

Description
Remove the two M5 Pozi-drive screws, which secure the front of the
fan inverter to the drive.
Proper tightening torque for reassembly is 4 N-m (35 lb.-in.).
Disconnect the fan motor cable under the inverter.

Remove the four M5 Pozi-drive screws, which secure the bottom of the
fan inverter to the drive.
Proper tightening torque for reassembly is 4 N-m (35 lb.-in.).
Disconnect the cables at X2, X8 and X3 (on left-hand and center
inverters); and X2 and X8 (on right-hand inverter).

Carefully remove the inverters by sliding them out towards the front of
the drive.

A

B

C

D

E

A

A

B

C

C

C

C

Important: Do not damage the output transformer when removing or

installing the inverter.