Rockwell Automation 20D PowerFlex 700H/S Frame 12 Replacement Power Structure User Manual

Page 11

Advertising
background image

PowerFlex® 700S and 700H Frame 12 Replacement Power Structures

11

4. Slide the old ASIC board out of its chassis.

5. Slide the new ASIC board into the chassis.

6. If you are installing a replacement power structure on a drive with AC

input, remove the X2 plug from its protective sleeve and plug the cable
into the X2 socket on the ASIC board.

7. Connect the other end of the cable connected to X2 on the ASIC board

to X13 on the Rectifier circuit board on the upper right side of the
power structure.

8. Connect the cable from the Feedback board to the X26 connector on the

ASIC board.

9. Plug the fan that mounts on the ASIC assembly cover into the X1

connector on the ASIC board.

ASIC Board

H11

H12

H13

H8

H9

H10

X6

X9

X15

X3

X4

X5

X2

X1

H4

H5

H6

H1

H2

H3

H7

X26

X11

To X13 connection on Rectifying board

X1 Fan connection

X26 Feedback
board connection

Advertising