26 TL-Series Electric Cylinders
Rockwell Automation Publication TLAR-IN001B-EN-P - February 2014
Configure and Tune Your Kinetix 300 Drive for an Electric Cylinder with MotionView On
Board Software
In this section you use the MotionView Onboard software to configure and tune your electric
cylinder.
Configure Your Kinetix 300 Drive
These steps assume that an electric cylinder and the Kinetix 300 drive are installed and wired as
one axis of a motion system.
For help using the Kinetix 300 drive as it applies to setting up your electric cylinder, refer to
. This procedure assumes that you are familiar with the
Kinetix 300 drive.
1. Open the MotionView Onboard software.
2. From the Drive Organizer, click Motor.
3. Verify that your electric cylinder model is displayed in the Motor Model field.
4. Click Change Motor.
The motor model automatically updates to the correct model number.
5. Click OK, then Click Yes.
6. Verify that the motor model matches the electric cylinder model connected to the drive.
7. From the Drive Organizer, choose General.
8. From the Drive Mode pull-down menu, choose Indexing.