Rockwell Automation 1440-SPD02-01RB XM-220 Dual Speed Module User Manual
Page 75

Publication GMSI10-UM004B-EN-P - May 2010
Specifications 67
Measured Parameters
Direction
Speed
Acceleration
Peak Speed
Gap (or transducer bias voltage)
Measured Units
Forward
Reverse
RPM
Direction of Rotation
Acceleration in RPM / Minute
Measurement Modes
Dual Channel
Single Redundant Channel
Reverse Rotation
Two sensors are used independently to
perform two separate speed, acceleration
and peak speed measurements.
One sensor is used to perform the speed,
acceleration and peak speed
measurements. If the current sensor fails,
the module automatically switches to the
second (redundant) sensor.
Two sensors are used to monitor both speed
and direction. The two sensors must be
mounted out of phase from each other so
that the rotational direction can be
determined by monitoring which sensor the
shaft keyway passes first.
Alarms
Number
Alarm Parameters
Operators
Hysteresis
8 alarms, fixed per channel
Alarm and danger pair provided for each of:
Speed
Acceleration
Zero Speed
Locked Rotor
Greater than
Less than
Inside range
Outside range
User configurable in software
XM-220 Technical Specifications
Product Feature
Specification