Rockwell Automation VSM-CE-1l, 3l, 3E Integrated Drive/Motor CE Filter Kits User Manual

Page 6

Advertising
background image

Publication D2-3449-1 March 2000

2000 Rockwell International Corporation. All rights reserved. Printed in USA.

1999 Rockwell Automation Corporation. All Rights Reserved

Reach us now at www.rockwellautomation.com

Wherever you need us, Rockwell Automation brings together leading
brands in industrial automation including Allen-Bradley controls,
Reliance Electric power transmission products, Dodge mechanical power
transmission components, and Rockwell Software. Rockwell Automation’s
unique, flexible approach to helping customers achieve a competitive
advantage is supported by thousands of authorized partners, distributors
and system integrators around the world.

Americas Headquarters, 1201 South Second Street, Milwaukee, WI 53204, USA, Tel: (1) 414 382-2000, Fax: (1) 414 382 4444
European Headquarters SA/NV, avenue Herrmann Debroux, 46, 1160 Brussels, Belgium, Tel: (32) 2 663 06 00, Fax: (32) 2 663 06 40
Asia Pacific Headquarters, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Reliance Electric Standard Drives Business, 24800 Tungsten Road, Cleveland, OH 44117, USA, Tel: (1) 888 374 8370, Fax: (216) 266 7095

Publication D2-3464 - March 2000

2000 Rockwell International Corporation. All rights reserved. Printed in USA.

VSM500 Integrated Drive/Motor CE Filter Option Specifications

VSM-CE-1I

VSM-CE-3I

VSM-CE-1E

VSM-CE-3E

Input Voltage

115/230 VAC

230/460 VAC

115/230 VAC

230/460 VAC

Input Phases

Single Phase

Three Phase

Single Phase

Three Phase

Frequency

50/60 Hz

Rated Current

14 amps

9 amps

14 amps

9 amps

Power Dissipation

5 watts

Leakage Current (Worst Case)

0.5 mA

Weight

0.33 Kg

(0.73 lb)

0.45 Kg

(0.99 lb)

4.72 Kg

(10.41 lb)

4.89 Kg

(10.78 lb)

Enclosure

Internal

NEMA 12/IP 65

Operating Temperature

0° to 40°C (32° to 104°F)

Storage Temperature

-40° to 85°C (-40° to 185°F)

Relative Humidity

5% to 95%, non-condensing

Vibration

1 G operational, 2.5 G non-operational

Shock

15 G operational, 30 G non-operational

Altitude

1000 meters (3300 feet) without derating. For every 91.4 meters (300 feet)
above 1000 meters, derate current by 1%. Above 3000 meters (10,000 feet),
consult your Reliance Electric Sales Office.

International Standards and
Approvals

UL

®

LIST

ED 966X

IND CONT EQ

UL508C

UL

®

LIST

ED 966X

IND CONT EQ

C

CSA 22.2

EMC Directive 89/336

LV:

EN 50178, EN 60204

EMC: EN 61800-3, EN 50081-1, EN 50082-2