PAGE 28

Batching Time Adjustment

The batching time adjustments allow the user to select

the time duration associated with the currently selected
output type. Two output types and times are available.

1. Feed interrupt has a range of 0.0 to 9.9 seconds.
2. Speed-up Table has a range of 0.00 to 5.00 seconds.

Select Count Source

The Output Count and Input Count keys select between

count at delivery and feeder, respectively. One key LED
will always be lit in Counter Setup to show the current
count source, see table 8. Chasing LEDs will activate in
the small display signifying the start setup mode. The next
sheet fed through will be timed from leading edge to
trailing edge and the delay time will be set to one half the
sheet time. Please note this must be redone if the delivery

speed is changed.

Table 8. Count Source Selection

Exit Counter Setup Mode

Pressing any of these keys will cause the counter to

change to a new mode.

2.3 Easy Mode and Continuous Cycle

Mode

2.3.1 Easy Mode and Continuous Cycle Mode

Enable EASY mode at parameter P25, see Table 3.

Select Easy Mode

Pressing this button enables the selection of either the

EASY mode or cYcL mode.

+

The batching count source will be the feeder
photoeye.

The batching count source will be whatever is
connected as the delivery photoeye.

0

+

+

Pressing these buttons will toggle between the EASY

mode or cYcL mode. Set EASY in the large display and

press again.

Select Continuous Cycle Mode

Pressing this button enables the selection of either the

EASY mode or cYcL mode

Pressing these buttons will toggle between the EASY

mode or cYcL mode. Set cYcL in the large display and

.press again.

Exit Run Mode

Pressing any of these keys will cause the counter to

change to a new mode.

2.4 Learn Mode

This key places the controller in learn mode. Learn
mode can only be activated if the folder is idle.

The learn mode allows the user to setup the suction

valve controller. Both manual and automatic setup is
accomplished in this mode. The large display (1) shows
two separate data items. The suction mode is shown on the
left and the sheet length is shown on the right. The small
display (2) shows the current gap length. The suction
length display is active. During Learn Mode, the Learn
Mode key LED indicates whether a valid sheet has been
learned.

Table 9. Learn Mode Status

When the LED is on, pushing the sheet start button will
feed a single sheet of paper. If the sheet is fed properly, the
indicator LED will go off. The suction mode will be set to
automatic. The length of the sheet will be set as the current
sheet length. The suction length will be set based on table
11 and the gap length will be set to 4 cm /1.50 inches.

No valid sheet has been read yet, the system is in
Single Sheet mode.

A valid sheet has been read and the DCT500 has
been setup to run. Single Sheet mode is off.

Job

Advertising