0 logic board status indicators – Baumfolder BAUM20: Pile Folder 1st Station (in 2005) User Manual

Page 31

Advertising
background image

PAGE 31 TP10243-3

Reset Function

Pressing and holding this key will result in a reset

function being activated after a 5-second countdown. The
function is based on the current large display selection, see
table 12. The large display (1) will show countdown to
reset in this manner. When the button is pressed the
message ‘CLr In 5’ will show on the large display (1). At
one second intervals the display will progress through ‘CLr
In 4’, ‘CLr In 3’, ‘CLr In 2’, ‘CLr In 1’, and finally will
show ‘CLEArEd’ when the reset action is complete.

0

Reset while showing Output Count will reset all job
variables.

Reset while showing batch data will reset Number
of Batches and reload the Batch Down Count.

Reference Name

Description

Designator
LED1

Tachometer Indicator

Tracks the Tachometer input.

LED2

Not Used

Turns on when MKE output is activated.

LED3

Suction Indicator

Tracks the Suction output.

LED4

K1

Status of Relay K1

LED5

Pile Down

Tracks the Pile down output.

LED6

Pile Up

Tracks the Pile up output.

LED7

Pile Indicator

Tracks the Pile outputs. If one of the Pile
outputs is on, this LED will be on.

LED8

Logic +5VDC Supply

Shows status of Logic +5VDC Supply

LED9

Isolated +5VDC Supply

Shows status of Isolated +5VDC Supply

LED10

Isolated +24VDC Supply

Shows status of Isolated +24VDC Supply

LED11

Kicker

Turns on when kicker output is activated.

Table 14. LED Status Indicators

3.0

Logic Board Status Indicators

Several of the controller functions are monitored with

LED indicators located on the Logic Board (see Table 14).
The status of all other inputs are shown on the 8 Digit
display in Machine Setup mode (see Tables 1 - 6).

Table 13. Reset mode Selection

Advertising