5 make ready mode – Baumfolder BAUM20: Pile Folder 1st Station (in 2005) User Manual

Page 29

Advertising
background image

PAGE 29 TP10243-3

Table 10. Suction Mode Symbols

Table 11. Suction Length Function

TWT-180 Mode

Leading Edge Control

Leading and Trailing Edge Control

+

+

+

If P06 is set to 0 (no knife is active) and 10 cm /4.0 inches. If
P06 is setting to 1, knifes are active.

Gap Length Adjustment

The minus and plus keys adjust the gap length. The gap
length range is 0.2” to 98.0” (0.5cm to 250cm).

Suction Length Adjustment

This is the same as in run mode

The suction length adjustment keys allow the user to

change the amount of suction applied to the current sheet
length. The display shows the percentage in 5% steps. All
of the bars must be totaled to get the value. The range of
adjustment is 5% to 50% of the current sheet length. If the
suction length is manually adjusted while the Learn Mode
LED is on, the suction length will no longer be the Single
Sheet suction length of 6.0”. The new suction length will
be based on the current sheet length and suction setting.

+

Select Suction Mode

These keys toggle between automatic control and cycle

mode. In the cycle mode, the suction valve will be on for
the suction length and off for the remainder of the sheet
length plus the gap length. No adjustments are made for
slipped sheets or process changes. The automatic mode
corrects for process changes and controls the timing of the
suction valve to maintain the user-selected gap. If the gap
is less than 1.5” (4.0 cm), the right hand decimal point of
the small display (2) will flash and the Leading edge
control will be active. If the gap is greater than or equal to
1.5” (4.0 cm), full Leading and Trailing edge control is
maintained. Refer to table 10 for suction mode symbol
definitions.

Sheet Length Adjustment

The sheet length adjustment keys allow the user to

override the automatic Learn Mode setting. When the user
changes the sheet length, the suction length will be
adjusted according to table 11. If a different suction length
is desired, the value may be overridden with the suction
length adjustment keys. The sheet length range is 10 cm /4
inches to 250 cm / 98.5 inches.

Sheet Length Setting

Resultant Suction Length Percentage

Greater than or equal to 30 cm.

30% of Sheet Length

Less than 30 cm., and greater than or equal to 27 cm.

25% of Sheet Length

Less than 27 cm., and greater than or equal to 24 cm.

20% of Sheet Length

Less than 24 cm., and greater than or equal to 21 cm.

15% of Sheet Length

Less than 21 cm.

10% of Sheet Length.

h

0

Exit Learn Mode

Pressing any of these keys will cause the controller to

change to a new mode.

2.5 Make Ready Mode

This key places the controller in the make ready mode.

The key LED goes on. In this mode the folder will only
feed single sheets and a batching output is issued for every
two sheets fed. This allows the operator to easily set up the
batching time.

Advertising