K5A - 18
5.0 Automatic Operation
Automatic ON/OFF
Funtion:
Automatic backgauge advance to the next step number
after cutting process
Automatic ON:
Press key
< after cut: automatic backgauge advance to next cut size;
display reads:
AUTOMATIC
Automatic OFF:
Press key
Attention!
When Automatic is switched on the following operations are
not
possible:
•
programming
•
automatic setting of backgauge through size input
Positioning check in automatic operation
For example, when a positioning process in automatic operation has been
interrupted (cutting position has not been reached!) and the operator tries to
release a cut in automatic mode after that, a visual and audible indication is
made "
GO TO POSITION".
When the position must be moved to:
Press key
twice