Troubleshooting, Troubleshooting procedures – Bowflex TreadClimber 5000 User Manual

Page 36

Advertising
background image

32

Owner’s Manual

Troubleshooting

Unless it is necessary to turn on the machine to do the procedure, always unplug the power cord

from the wall outlet, and wait 5 minutes before performing repairs.

Some components of the equipment can be heavy or awkward. Enlist the service of a second person when you

do maintenance steps involving these components. Do not try to do heavy or awkward steps on your own.

WA R N I N G

A T T E N T I O N

D A N G E R

IMMEDIATE ACTION REQUIRED

C A U T I O N

Condition / Problem

Things to Check

Solution

Unit will not power up/turn on/

start

Outlet

Make sure outlet is functioning correctly. Verify this

by plugging another object (ex: lamp) into the outlet.

If outlet is connected to a light switch, check to make

sure it is on. If outlet is not functioning find a working

outlet.

Power cord not plugged in

Make sure the power cord is firmly secured to AC inlet

on the unit and firmly inserted into a non-GFI (and non-

AFI) wall socket.

Power switch turned off

Make sure the power switch at the rear of the unit is in

the “ON” position.

Safety key not plugged in

Plug Safety Key into console. (See Emergency Stop

Procedure within the Important Safety Precautions

section.)

LED Diagnostic needed

Remove rear plastic covers and contact customer

service for assistance.

Speed displayed is not accurate Display set to wrong unit of

measure (English/Metric)

Change display units (See Owner’s Manual).

Out of calibration

Re-calibrate machine. (See Calibration procedure in

this manual.)

Heart rate not displayed while

using chest strap (TC5000 only)

Transmitter not making good

contact with skin

Make sure heart rate monitor is under clothing, against

the skin, and as high under the pectoral muscles as is

comfortable. Use saline solution (saliva or contact lens

solution) to wet the electrode areas on the sensor unit.

Electromagnetic interference Turn off any television, AM radio, microwave, or

computer within 6 feet (2 meters) of the TreadClimber

®

fitness machine. Try positioning the machine in another

area.

Chest strap transmitter

Test chest strap with another HR monitoring device

such as HR watch or a machine at a gym. If

transmitter has good skin contact and still is not

found to be emitting HR signal, replace chest strap

transmitter.

HR receiver

If chest strap is known to work with other devices and

no sources of interference are present, or console has

been tested with a Pulse Simulator and is not receiving

the signal, replace the HR receiver.

Walking belt misalignment

Rear belt guides

Belts should ride on top of triangular black belt guides

at rear of treadles.

Tracking adjustment

Belts are not required to be perfectly centered and

are typically farther out in the rear than they are in the

front. This may vary depending on user’s stride. If belt

is tracking to one side far enough to cause rubbing of

belt, follow Belt Alignment procedure in this manual.

Troubleshooting Procedures