Functional test, Figure 9 test display, no malfunction – Bird Technologies SCC8 Series-Manual User Manual

Page 28

Advertising
background image

Maintenance

14

Functional Test

1. Disconnect the AC power cable and turn the power meter off.



Note:

The On/Off switch on the rear panel of the meter should be On.

2. Connect the AC power cable.
3. Press the On/Off button on the front panel of the power meter whilehold-

ing down the FWD and SWR push buttons, .

4. Immediately release all three.
5. Ensure that both of following happen:

z

The power meter’s model number and revision date should scroll

across the display.



Note:

If a dash “–” is displayed instead, then the meter is malfunc-

tioning.

z

The power sensor’s model number and revision date should scroll

across the display.



Note:

If a dash “–” is displayed after the power meter data, then

the power sensor is malfunctioning.

Figure 9 Test Display, No Malfunction

PROBLEM

POSSIBLE CAUSE

CORRECTION

Power meter has no
power

Have the batteries been
charged?

Recharge the batteries.

Is the power meter’s AC power
cord connected to the terminal
strip?

Connect the power cord.

Is the Cal Cart’s AC power cord
connected to the AC line?

Connect AC power.

Is the ON/OFF rocker switch on
the rear panel set to OFF?

Set the switch to ON.

Unplug the Cal Cart. Has the
power meter fuse blown?

Replace fuse (See “Replacing
Fuses” on page 18).

Dash moves across
the display

Is the AC power cord defective? Replace AC power cord.
Is the sensor cable connected
to both the power meter and
power sensor?

Connect sensor cable.

Is the sensor cable defective?

Replace sensor cable.

Display blank or not
updating

Have the batteries been
charged?

NO: Recharge battery
YES: Return meter for service.

Power meter turns off
while on battery power

Is “LO BAT” displayed?

YES: Recharge battery
NO: Return meter for service.

Push buttons do not
respond

Test the push buttons (See
“Push Button Test” on page 15
).
Are they defective?

Return meter for service.

Every segment on the
display is lit

Return meter for service.

Meter’s

Model

Number

Meter’s

Software

Rev. Date

Sensor’s

Model

Number

Sensor’s
Software

Rev. Date

– . . 4 4 2 1 . . – 0 7 . 0 1 . 0 2 – . . 4 0 2 1 . . – 0 7 . 0 1 . 0 2 –

Advertising