Replacing batteries, Figure 13 batteries – Bird Technologies SCC8 Series-Manual User Manual

Page 33

Advertising
background image

Maintenance

19

Replacing Batteries

1. Disconnect the AC power cord from the AC mains supply.
2. Remove the four screws that secure the top cover.
3. Lift the top cover to access the attached ground wire then disconnect the

ground wire and remove the cover.

4. Unfasten the battery retaining belts then remove the battery tubes (Figure 13).



Note:

Be sure to note the polarity and orientation of the battery

tubes before removing them.

5. Remove the batteries from each tube and insert replacement batteries.



Note:

Be sure to note the polarity (positive and negative) arrange-

ment of the batteries.

6. Install the battery tubes into the unit and secure with the retaining belts.



Note:

Be sure to position the retaining belts as they were before

removal and tighten them securely.

7. Connect the ground wire to the top cover.
8. Install the top cover.
9. Secure the top cover with the four screws removed earlier.

Figure 13 Batteries

WARNING

Exposed AC line voltage (115 VAC or 230 VAC). Disconnect the power cord

from the AC line before replacing the batteries. Failure to comply may

result in severe electrical shock or death.

Item

Description

1

Battery retaining belt

2

Battery tube (batteries inside)

X4

X4

Advertising