Load Troubleshooting

Repair

Figure 10 Cal Cart Outline

PROBLEM

POSSIBLE CAUSE

CORRECTION

Blower not
operating

Is the load’s AC power cord
connected to the terminal strip?

Connect the power cord.

Is the Cal Cart’s AC power cord
connected to the AC line?

Connect AC power.

Unit turned off.

Set the line switch to ON.

Fuse burnout.

Replace fuse (See "Replacing
Fuses" on page 18).

Coolant leaking

Loose connections.

Tighten drain plug and all
connections.

Worn or cracked tubing.

Replace defective tubing.

Excessive
reflected power

Resistor’s DC resistance has
changed.

Check DC resistance. See "DC
Resistance" on page 12).

WARNING

To avoid personal injury, disconnect the power cord from the AC line before

performing any maintenance, including fuse replacement.

WARNING

Never attempt to connect or disconnect RF equipment from the

transmission line while RF power is being applied.

Leaking RF energy is a potential health hazard.