Push button test – Bird Technologies SCC8 Series-Manual User Manual

Page 29

Advertising
background image

Maintenance

15

Push Button Test



Note:

This test checks that the push buttons and display are function-

ing properly. If a push button is malfunctioning, return the power meter.

1. Disconnect the power sensor.
2. Turn the power meter On.



Note:

After the power up display disappears, three dashes “– – –”

should scroll across the display.

3. “AUTO” and “FWD” should be displayed, and a reading of “.000 W”.
4. Press RFL. “FWD” should change to “RFL” on the display.



Note:

The reading should remain the same.

5. Press SWR.



Note:

“RFL” should change to “SWR”. “.000 W” should change to

” (underrange error).

6. Hold down MIN.



Note:

” should change to “

” (overrange error).

7. Release MIN.



Note:

” should change to “

”.

8. Hold down MAX.



Note:

” should change to “.000”.

9. Release MAX.



Note:

“.000” should change to “

”.

10. Press dBm.



Note:

“SWR” should change to “dBm”.

11. Press dBm.



Note:

“dBm” should change to “SWR”.

12. Press FWD.



Note:

“SWR” should change to “FWD”. “

” should change

to “.000 W”.

13. Press LIGHT.



Note:

The back-light should turn on.

14. Press LIGHT.



Note:

The back-light should turn off.

15. Press s (up).



Note:

The power meter should change ranges each time it is

pressed until it reaches “.000 KW”.

16. Press t (down).



Note:

The power meter should change ranges each time it is

pressed until it reaches “.000 W”.

17. Turn the power meter OFF.

Advertising