Replacement parts, Cal cart, Bird 8640s series moduloads – Bird Technologies SCC8 Series-Manual User Manual

Page 43

Advertising
background image

Maintenance

29

Bird 8640S Series Moduloads

Replacement Parts

Cal Cart

Frequency Range

1 kHz – 900 MHz

Power Rating

25 kW continuous duty

Mode

CW, AM, FM, SSB, TV and certain pulse types

Impedance, Nominal

50 ohms

VSWR, Max

1.10:1

Cooling Method

Water dielectric and forced air convection

Coolant

*

* Below 5°C, ONLY use 35% E.G. and 65% Dist. H

2

O mixture

Distilled water or distilled water/ethylene glycol
mixture

Coolant Capacity

9 qts. (8.5 L) nominal

AC Power

115/230 Vac @ 50/60 Hz

Fuse Rating

115 Vac
230 Vac

15 A (3AB time delay)
8 A (5x20 mm time delay)

Operating Temperature

Water only
35% Ethylene Glycol

† Above 30°C (86 °F) with water only, or 25°C (77 °F) with a 35% ethylene gly-

col mixture, derate power to 20 kW max.

5 to 45

°C (41 to 113 °F)

0 to 35

°C (32 to 95 °F)

Storage Temperature

Water only
35% E.G.

+5 to +50 °C (41 to 122 °F)
–20 to +50 °C (–4 to +122 °F)

Description

Qty

Part Number

Power Meter Fuse,
IEC (5 x 20 mm) Type T

115 Vac, T630 mA
230 Vac, T315 mA

1

5A2257-14
5A2257-11

Cord, AC Power, Power Meter

115 Vac
230 Vac Harmonized

1

5-1286
5A2416

Plug, 115 Vac

1

5A2626

Cable, Sensor

1

4421-038

Grommet

1

SA2617-20

Cordreel

1

4421A383-2

Handle

1

4421A385

Advertising