Stairs —

Given Only Floor-to-Floor Rise

You’re building a stairway with a total rise of 9 feet 11 inches. Your
desired riser height is 7-1/2 inches and desired tread width is 10
inches. The desired headroom is 6 feet 8 inches and floor thickness
10 inches*. Find all stair values, then calculate the run.

*Note: Headroom and floor thickness are required to calculate the length of the stair-
well opening.

KEYSTROKE

DISPLAY

1. Enter known rise:

o o

0.

9 f 1 1 i r

RISE 9

FEET

11

INCH

2. Recall stored desired stair riser height:

® 7

R-HT STORED 7-1/2

INCH

3. Recall stored desired stair tread width:

® 9

T-WD STORED 10

INCH

4. Recall stored desired floor thickness:

® 8

FLOR STORED 10

INCH

5. Display stored headroom (via Preference Setting Mode):

З Я Я Я Я

HDRM 6

FEET

8

INCH

6. Find riser height, number of risers, riser underage/overage, tread
width, number of treads, tread overage/underage, length of stairwell
opening, stringer length and angle of incline. As a final step, calcu-
late the run.

s

R-HT 7-7/16

INCH

s

RSRS 16.

s

R+/– 0

INCH

s

T-WD 10

INCH

s

TRDS 15.

s

T+/– 0

INCH

s

OPEN 10

FEET

1

INCH

s

STRG 15

FEET

6-15/16

INCH

s

INCL 36.64°

s

RUN 12

FEET

6

INCH

s

*

RISE STORED 9

FEET

11

INCH

*Continuous presses of

s

will also recall stored desired riser height, tread, head-

room and floor thickness values.