C. Link – Multi-Unit Linking

The proprietary C. Link (control link) connection allows multiple 702T, 702T, 722, and 744T recorders

to be connected and clocked together. The C. Link also enables the CL-1 Remote Control and Key-

board interface to control the 702T with an attached keyboard or via switch closures.

When linked, recorders have a master/slave relationship. The master recorder and the slave unit will

share sample accurate start and stop record times. Multiple units can be daisy-chained together to

record many tracks. The C. Link protocol links carries the following data:

• word clock

• time code information (702T and 744T only)

• RS-232 machine transport data

master

unit

slave

unit

slave

unit

To link units:

1

. Connect multiple units as shown in the illustration.

2.

Set all linked recorders to the same sample rate, bit depth, file format, and time code frame rate (for

702T and 744T units used). This will ensure that all files generated are compatible.

3.

Set scene and take numbers on all linked recorders to the same starting file name. There is no file name

synchronization with multiple unit linking.

When linked, record start and stop on slave units will not affect units “above” it in the linked chain.

This makes it possible for units to get out of synchronization if a unit other than the master is set to

record or stop. Using the master unit will assure that all machines begin and end recording together.

Master/Slave relationships between C.Linked recorders is established immediately after the C.Link

Out to C.Link In connection is made. To reverse the Master/Slave relationship, power down all

recorders, establish the new Master/Slave relationships by reconnecting the C.Link Out to C.Link In

connectors in the desired sequence, then power on all units in order of their Master/Slave relation-

ships

The master recorder in a C.Link connection can not receive wordclock sync from anywhere else. It must
be the master wordclock source for all C.Link slaves.

The C. Link jack is a proprietary RS-232 port. Under no circumstances should analog or digital telephone
lines be connected to either jack. Serious damage may result.