Tweco 1000 Merlin(Sept1999) User Manual

Page 20

Advertising
background image

INSTALLATION PROCEDURES

16

Manual 0-2731

PLASMA GAS

Fitting

SECONDARY

GAS Fitting

Plasma Gas

Hose

Secondary Gas

Hose

A-02349

Figure 3-3 Gas Connections Using Gas Cylinders

c. Connect the gas supply hose from the second-

ary gas supply directly to the input fitting on
the rear panel of the Power Supply marked
SECONDARY.

C. Using Plasma Shop Air And Secondary

High-Pressure Gas Cylinder

NOTES

Refer to the regulator manufacturer’s specifications
for installation and maintenance procedures. Re-
fer to Section 6.05, System Options and Accesso-
ries, for a listing of available high-pressure regu-
lators.

Do not use an air line filter with high pressure gas
cylinders.

1. Examine the cylinder valves to be sure they are clean

and free of oil, grease or any foreign material. Mo-
mentarily open each cylinder valve to blow out any
dust which may be present.

WARNING

Do not stand in front of the valve outlet when open-
ing.

2. Each cylinder must be equipped with an adjustable

high-pressure regulator capable of pressures up to 125
psi (8.6 BAR) maximum and flows of up to 700 scfh
(328 lpm) for cutting or gouging.

CAUTION

Maximum input pressure to the internal regula-
tor on the Power Supply must not exceed 125 psi
(8.6 BAR).

NOTE

A typical 50 lb. CO2 cylinder can deliver a con-
tinuous flow rate of 35 scfh (16.5 lpm). To obtain
the required flow rate for the torch, it may be nec-
essary to manifold several CO2 cylinders. Con-
tinuous flow requirements will depend on the spe-
cific application and duty cycle.

3. Connect the gas supply to the Power Supply per

the following:

a. Remove the secondary gas hose and adapter

from the SECONDARY fitting at the rear panel.

PLASMA GAS

Fitting

SECONDARY

GAS Fitting

Plasma Gas

Hose

Secondary Gas

Hose

A-02356

Adapter Fitting

Figure 3-4 Removal Of Factory Installed Hardwre

b. Connect the gas supply hose from the second-

ary gas supply directly to the input fitting on
the rear panel of the Power Supply marked
SECONDARY.

Advertising