SERVICE

36

Manual 0-2731

A-02152

Filter Holder

Filter

Figure 5-1 Coolant Filter Assembly

C. In-Line Filter Assembly

The in-line filter screen should be cleaned periodically.
To gain access to the In-Line Filter Assembly remove the
right side panel (viewed from the front of unit) of the
Power Supply. Remove the filter screen by unscrewing
the filter holder from the In-Line Filter Assembly. Clean
the filter screen by rinsing with hot soapy water. Remove
soap residue by rinsing with clean hot water. Be sure
that all the soap has been removed and the screen is dry
of water before re-installing in the In-Line Filter Assem-
bly.

A-02153

Filter Holder

Filter

Figure 5-2 In-Line Filter Assembly

D. Coolant Level and Conductivity

1. Coolant Level

The coolant level should be checked every day at
the rear panel coolant gauge. If the coolant in the
reservoir is more than 2 inches (50mm) from the
top of the reservoir then add Torch Coolant.

2. Coolant Conductivity

The coolant conductivity level should be checked
if the pilot doesn't start.

Check the condition of the deionizer bag in the
reservoir basket, if the bag is yellowish brown
(straw color) replace the bag and coolant (see
NOTE).

NOTE

To accurately measure the coolant conductivity it
is recommended to use a Conductivity Sensor simi-
lar to Thermal Dynamics Model TDS-73 (Catalog
# 7-2844).

E. Draining and Replacing Coolant

Remove the old coolant from the Power Supply reservoir
per the following procedure:

1. Disconnect the coolant input hose to the Coolant

Filter Assembly at the rear panel.

2. Carefully lower the hose out the right side of the

Power Supply and drain the coolant into an ac-
ceptable container.

CAUTION

Handle and dispose of the used coolant per recom-
mended procedures.

Coolant

Hose

Coolant Hose

Connection

A-02354

Figure 5-3 Draining Coolant From Reservoir

3. Reconnect the hose to the Coolant Filter Assembly.

4. Remove Coolant Reservoir Filler Cap and install

new coolant and deionizer bag.

Advertising