INSTALLATION PROCEDURES

b. Remove the panel by lifting the panel up and

off the studs being careful not to damage the
wiring.

c. Locate the Wiring Harness with Connector at-

tached, 14-pin CPC type, in the parts supplied
with the Remote Arc Starter.

d. At the rear of the Power Supply Bulkhead Panel

place the connector into the spare hole on the
left side as viewed from the front.

e. Secure the connector to the Power Supply Bulk-

head Panel with two screws.

J11 on CD Start

PC Board

Remote Arc Starter

Wiring Harness

Assembly

Bulkhead

Panel

Ground Stud

A-02287

Figure 3-17 Installation Of Wiring Harness

f. Locate the ground stud and remove one nut

and star washer.

g. Place the two wires with ring terminals over

the ground stud and secure with the nut and
star washer.

h. Locate the CD Start PC Board mounted to the

Center Chassis on the Power Supply.

i. Disconnect the plug connected to J11 on the right

side of the PC Board.

j. Reconnect the J11 plug to the mating connector

on the Wiring Harness with Connector installed
above.

k. Re-install the Front/Access Panel.

l. Connect the end of the Control Cable to the 14-

pin CPC connector mounted to the Power Sup-
ply Bulkhead.