INSTALLATION PROCEDURES

22

Manual 0-2731

A-02282

Torch Leads

Secondary Gas

Plasma Gas (+)

Left-Hand Thread

Coolant Supply

Left-Hand Thread

Coolant

Return (-)

Torch Lead Shield

Figure 3-14 Torch Leads Connections

4. Connect the separate shield lead with ring termi-

nal to the mounting stud on the bulkhead panel.

5. Check the torch for proper parts assembly.

CAUTION

The torch parts (gas distributor, electrode, tip, and
shield cup) must correspond with plasma and sec-
ondary selection, output current level, and type of
operation (cutting or gouging). Refer to Section
4.04, Torch Parts Selection.

6. Connect the Torch Supply Leads components to

the Remote Arc Starter (see NOTE).

C. Connecting Torch Supply Leads

WARNING

Disconnect primary power at the source before dis-
assembling the torch or torch leads.

Connect one end of the Torch Supply Leads to the inter-
nal bulkhead inside the Arc Starter Box per the follow-
ing:

1. Remove the cover from the Arc Starter Box if in-

stalled.

2. Feed the four hose assemblies on the Torch Supply

Leads through the boot on the lead end of the Arc
Starter Box. The lead end of the Arc Starter Box
has a boot and control connector installed.

3. Connect the four hose assemblies to the internal

bulkhead per the following figure.

A-02283

Plasma Gas (+)

Left-Hand Thread

Coolant Supply

Left-Hand Thread

Secondary

Gas

Coolant Return (-)

Control

Cable

Figure 3-15 Torch Supply Leads Connections

4. Connect the other end of the Torch Supply Leads

fittings onto the mating connections at the bulk-
head panel of the Plasma Power Supply.

A-02167

Control Cable

Connector

Standoff Control or CNC

Interface Cable

Power Supply

Torch Bulkhead

Figure 3-16 Torch Supply Leads Connection To

Power Supply

5. Connect the control cable connector to the mating

connector on the end of the Arc Starter Box.

6. The Power Supply requires internal changes when

the Optional Remote Arc Starter is to be used per
the following procedure:

a. Open the Front Control/Access Panel.