Tweco 1000 Merlin(Sept1999) User Manual

Page 37

Advertising
background image

Manual 0-2731

33

OPERATION

A-02258

Logic PC Board

SW5

1 2

Figure 4-8 High/Low Speed Auto-Restart Switch

SW5 Location

Select the desired function as shown in the following
chart:

High/Low Speed Auto-Restart Function

Speed

SW5-1

SW5-2

High

0 (OFF)

0 (OFF)

Low *

1 (ON)

1 (ON)

* = Factory Setting

NOTE

The ON position is in the direction of the arrow on
the PC Board next to the switch.

B. Gas Pre-Flow Delay (SW3)

The pre-flow delay allows time for gases to flow to the
torch when the torch is activated. Pre-flow is immedi-
ately followed by pilot arc initiation. Gas Pre-Flow De-
lay is set depending on the total torch lead length used
in the system. All power supplies are factory set at 2 sec-
onds and must be reset either to 3.4 or 4 seconds as re-
quired if total torch lead length in the system is over 60 ft
(18.3 m).

A-02288

Logic PC Board

SW3

1 2

Figure 4-9 Gas Pre-Flow Delay Switch SW3

Location

Select the proper gas pre-flow time for the total torch lead
length as shown in the following chart:

Pre-Flow

(Seconds)

Total Torch

Lead Length

SW3-1

SW3-2

2 *

0 - 60 ft

(0 - 18.3 m)

1 (ON)

1 (ON)

3.4

61 - 85 ft

(18.6 - 25.9 m)

1 (ON)

0 (OFF)

4

86 - 125 ft

(26.2 - 38.1 m)

0 (OFF)

0 (OFF)

Gas Pre-Flow Delay Function

* = Factory Setting