Section 4: operation, 01 introduction, 02 functional overview – Tweco 1000 Merlin(Sept1999) User Manual

Page 29: 03 front and rear panel descriptions, Section 4, Operation

Advertising
background image

Manual 0-2731

25

OPERATION

SECTION 4:

OPERATION

4.01 Introduction

This section provides a description of the Power Supply
operating controls and procedures. Identification of the
Front and Rear Panel components is followed by operat-
ing procedures.

4.02 Functional Overview

The Power Supply provides a degree of operating flex-
ibility and the use of simple controls.

4.03 Front and Rear Panel

Descriptions

This sub-section provides specific functional descriptions
of the Power Supply front and rear panel operating con-
trols, indicators and connections. The Power Supply has
three main front panels and one rear panel. Each panel is
described in this sub-section as to the functions of the
connections, switches, and indicators.

Control/Access

Panel

Lower Front

Panel

Rear

Panel

A-02169

Gas Control Panel

Lifting Eye

Figure 4-1 Main Front Panels

A. Lower Front Panel

1

2

A-02170

Figure 4-2 Lower Front Panel

1. Work Cable Strain Relief

Strain relief to secure the factory installed work cable
with ring terminal to the Power Supply.

2. Torch Leads Boot

Connection inside at the bulkhead for the Torch Leads
Assembly. The connections supply all the required
signals, gases, and coolant for the torch.

B. Control/Access Front Panel

NOTE

This panel is the access cover to the bulkhead area.

1. ON/OFF Switch

ON position activates all system control circuits when
remote or CNC enable is ON.

OFF position deactivates control circuits.

2. RUN/SET Switch

RUN position is used for torch operation.

SET position is used for setting gas pressures and
purging torch leads.

3. Current Control

Selects output current from 30-100 amps for the ap-
plication on various materials and thicknesses.

Advertising