05 input power connections, 06 input voltage selection – Tweco CE PAK Master 150XL Without Latch Circuit User Manual

Page 20

Advertising
background image

INSTALLATION

3-2

Manual 0-2696

3.05 Input Power Connections

The Power Supply accepts input voltages in ranges from 208/
230/460 VAC or 220/380-415 VAC, 50 or 60 Hz, three-phase power.

NOTE

Refer to Section 3.06, Input Voltage Selection.

A. Electrical Connections

The power source must conform to local electric codes. For
suggested circuit protection and wiring requirements refer to
Appendix 1.

B. Input Voltage Selection

The Power Supply is factory-wired for 380-415 VAC or 460 VAC,
three-phase input as ordered. For any other input voltage, the
Power Supply must be changed using the procedures in Sec-
tion 3.06.

C. Opening Power Supply Enclosure

The left side panel of the Power Supply must be removed
to gain access to the input power connections and the
input voltage selection. Use caution when removing the
panel as there is a ground wire connected to the inside of
the panel.

WARNING

Disconnect primary power at the source before as-
sembling or disassembling the Power Supply, torch
parts, or torch and leads assemblies.

1. Remove input power from the unit.

2. Loosen the two bottom screws in the slotted holes of the

desired Side Panel (viewed from the front of the unit).

3. Remove the remaining screws which secure the Side

Panel to the Power Supply.

4. Pull the top of the Panel out and then lift up to re-

move the panel from the Power Supply a short dis-
tance (see NOTE).

NOTE

There is a ground wire attached to the inside of the
side panel.

5. Remove the nut securing the ground wire to the side panel

and remove the ground wire.

A-02074

NOTE: Art may differ
from actual unit.

Figure 3-1 Removing Left Side Panel

6. Remove side panel from unit and set aside.

7. To reinstall the side panel do the following:

a. Reconnect the ground wire to the panel.

b. Place the side panel onto the frame and slide the top

edge under the lip on the top panel.

c. Reinstall all the screws to secure the side panel.

3.06 Input Voltage Selection

NOTE

For power supplies to use 575 VAC input power, the
unit must be set up for 460V three-phase operation
and the Optional 575V Transformer Assembly must
be installed.

The Power Supply has two voltage settings; HIGH VOLT-
AGE (380-415/460 VAC) or 208/230 VAC. All Power Sup-
plies are factory-wired for 380-415 VAC or 460 VAC, three-
phase input, as ordered. Input voltage selection is accomplished
by:

• Switching an internal voltage selection block and auxil-

iary transformer input connector inside the Power Sup-
ply

• Verifying the cable size conforms to the table in Appendix 1.

WARNING

Disconnect primary power at the source before
assembling or disassembling the power supply,
torch parts, or torch and leads assemblies.