Tweco CE PAK Master 150XL Without Latch Circuit User Manual

Page 25

Advertising
background image

Manual 0-2696

3-7

INSTALLATION

A-02948

T-Fitting

Gas Regulator

Supply Hose

1/4 NPT - Inert B, R.H

Fitting

Figure 3-8 Connection Using Single Gas Cylinder

• Using Separate Gas Cylinders for Plasma and Sec-

ondary Gas

If the Plasma and Secondary gases will be different or
two separate high pressure cylinders are to be used,
connect the gas regulator supply hoses to the Power
Supply as follows:

a. Remove the Plasma and Secondary Gas Hoses and

T-Fitting from unit by disconnecting the hoses
from the Inert-B Adapter Fittings at the Power Sup-
ply air regulators.

b. Connect the customer supplied gas cylinder sup-

ply hose from the plasma gas source directly to the
input fitting at the PLASMA air regulator of the
Power Supply.

c. Connect the customer supplied gas cylinder sup-

ply hose from the secondary gas source directly to
the input fitting at the SECONDARY air regulator
of the Power Supply.

Plasma Gas
Supply Hose
From Gas
Cylinder

Plasma Air
Regulator Assemby

Inert B Fittings

Secondary Air
Regulator Assembly

Secondary Gas
Supply Hose From
Gas Cylinder

A-02331

Figure 3-9 Connection Using Two Gas Cylinders

D. Using Plasma Shop Air and Secondary

High Pressure Gas Cylinder

NOTES

Refer to the manufacturer’s specifications for in-
stallation and maintenance procedures. Refer to
sales literature for a listing of available high-pres-
sure regulators and accessories.

Do not use an air line filter with high pressure regu-
lators.

1. Examine the cylinder valves to be sure they are clean

and free of oil, grease or any foreign material. Mo-
mentarily open each cylinder valve to blow out any
dust which may be present.

WARNING

Do not stand in front of valve outlet when opening.

2. Each cylinder must be equipped with an adjustable high-

pressure regulator capable of outlet pressures up to 100 psi
(6.9 bar) maximum and flows of up to 400 scfh (188.7 lpm).

CAUTION

Pressure should be set at 100 psi (6.9 bar) at the
high pressure gas cylinder regulator.