5-5

SERVICE

3. Actual input voltage does not correspond to voltage

selection inside unit

a. Check actual line voltage vs. voltage selection (in-

side of unit)

4. Customer's main power line fuse(s) blown

a. Check main power panel fuse(s) and replace as re-

quired.

5. Unit internal fuse blown or loose

a. If blown, double check input voltage vs. voltage

selection (inside of unit) and replace fuse per
subsection 5.06-C. If fuse blows again, return
unit to an authorized service center.

6. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

B. AC Power INDICATOR ON; TEMP indicator ON

1. Unit is overheated

a. Allow unit to cool down for about 5 minutes.

Make sure the unit has not been operated be-
yond duty cycle limit.

2. Airflow obstructed

a. Check for obstructed air flow and correct con-

dition.

3. Fan(s) blocked

a. Check and correct condition

4. Input line voltage is below 75% of rated level

a. Check and connect to proper input power line

5. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

C. Torch will not pilot when torch switch is activated

1. RUN/SET switch in SET position

a. Move switch to RUN position.

2. Switch activated during 8 second inrush time

a. Release switch and wait until AC INDICATOR

stops flashing before activating switch again

3. Faulty torch parts

a. Inspect torch parts and replace if necessary (re-

fer to Instruction Manual supplied with torch).

4. Gas pressure too high or too low

a. Set plasma gas pressure to 65 psi (4.5 bar) and sec-

ondary gas to 60 psi (4.1bar).

5. Faulty components in unit

a. Return for repair or have qualified technician repair

per Service Manual.

D. AC Power INDICATOR ON; Fans operating; No cutting

output

1. Torch not properly connected to power supply

a. Check that torch leads are properly attached to power

supply

2. Shield cup not properly installed on torch

a. Check that shield cup is fully seated against torch

head (do not overtighten if screwed on)

3. Faulty components in unit

a. Return for repair or have qualified technician repair

per Service Manual.

E. Low cutting output with no control

1. Incorrect setting of CURRENT control

a. Check and adjusted to proper setting.

2. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

3. Poor input or output connections

a. Check all input and output connections.

F. Erratic or improper cutting output

1. Poor input or output connections

a. Check all input and output connections.

2. Faulty torch parts.

a. Replace with new torch parts.

G. AC Power Indicator ON; Cutting output available;

Fan(s) not operating

1. Fan blades blocked

a. Check and clear blades.

2. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.