Tweco CE PAK Master 150XL Without Latch Circuit User Manual

Page 26

Advertising
background image

INSTALLATION

3-8

Manual 0-2696

3. Connect the SECONDARY gas supply to the rear of the

Power Supply as follows:

a. Remove the factory installed plug fitting from the

end of the T-Fitting on the "Y" Hose Assembly.

b. Disconnect the Secondary Hose from the T-Fitting

and install the plug removed above into the hole.
This will prevent lost of the plasma gas when all
connections are made.

c. Remove the Secondary Hose from the Inert-B Fit-

ting at the Secondary air regulator of the Power
Supply.

d. Connect the customer supplied gas cylinder sup-

ply hose from the secondary gas source to the In-
ert-B Fitting on the SECONDARY air regulator of
the Power Supply.

4. Connect the PLASMA shop air supply to the rear of the

Power Supply as follows:

a. Locate the 1/4 NPT to #4 (6 mm) barbed hose fitting

shipped inside the Torch Spare Parts Kit.

b. Install the supplied barbed fitting into the input of

the T-Fitting.

Plasma Air

Regulator Assemby

A-02332

T-Fitting

Inert-B Fitting

Secondary Air

Regulator Assembly

Secondary Gas

Supply Hose From

Gas Cylinder

Plug Fitting

Barbed Hose Fitting

Gas Supply

Hose

Hose Clamp

Plasma Gas

Supply Hose

Figure 3-10 Shop Air and Gas Cylinder

Connections

3. Tighten the barbed fitting.

4. Connect the plasma air supply hose (see NOTE) to the

barbed fitting and secure with a customer supplied
hose clamp.

NOTES

The customer supplied hose must be at least a #4 hose
(1/4 in or 6 mm I.D.) to provide adequate air flow.

E. Using Plasma Shop Air with Optional Two

Stage Filter Assembly, and Secondary High
Pressure Gas Cylinder

NOTES

Do not use an air line filter with high pressure regu-
lators.

For units where the Optional Two Stage Air Line
Filter has not been factory installed, install the Fil-
ter Assembly according to the instructions provided
with the assembly.

1. Connect the PLASMA Shop Air to the Two Stage Fil-

ter on the rear of the unit as follows:

a. Locate the 1/4 NPT to #4 (6 mm) barbed hose

fitting located inside the Torch Spare Parts Kit.

b. Install the barbed fitting into the input port

(IN) of the Two Stage Air Line Filter.

c. Tighten the barbed fitting.

d. Connect the PLASMA air supply hose (see

NOTE) to the barbed fitting and secure with a
customer supplied hose clamp.

NOTE

The customer supplied hose must be at least a #4
hose (1/4 in or 6 mm I.D.) to provide adequate air
flow.

A-02333

Two Stage

Filter

Assembly

Barbed Hose

Fitting

Gas Supply Hose

to Shop Air

Hose

Clamp

Plasma Air Regulator

Secondary
Air Regulator

Gas Supply Hose
to Gas Cylinder

Figure 3-11 Shop Air with Optional Filter and Gas

Cylinder Connections