11 filling power supply coolant, 11 filling power supply coolant -14 – Tweco CE PAK Master 150XL Without Latch Circuit User Manual

Page 32

Advertising
background image

INSTALLATION

3-14

Manual 0-2696

D. Routing Of Torch Leads

1. To minimize RF interference, position torch leads as far as

possible from any CNC components, drive motors, control
cables, or primary power lines. If cables have to pass over
torch leads, do so at an angle. Do not run the plasma con-
trol or other control cables in parallel with the torch leads in
power tracts.

2. Keep torch leads clean. Dirt and metal particles bleed off

energy, which causes difficult starting and increased chance
of RF interference.

3.11 Filling Power Supply Coolant

The ambient temperature of the environment where the Power
Supply will be located determines the coolant to be used. The
Extra-Cool

TM

Torch Coolant supplied with the system can be

used in ambient temperatures down to 10° F (-12° C).

Optional Ultra-Cool

TM

Torch Coolant should be used in areas

where the ambient temperature drops down to -27° F (-33° C).

CAUTION

Use only Thermal Arc Torch Coolant. Use of any
other coolant can result in torch damage, insuffi-
cient thermal protection, and/or pilot arc interfer-
ence.

1. Locate the coolant deionizer bag and remove from

the plastic shipping bag.

2. Remove the coolant filler cap from the reservoir

at the rear of the Power Supply.

3. Carefully pour enough of the supplied Thermal Arc

Torch Coolant into the reservoir to fill it.

4. Reinstall the reservoir coolant filler cap.

5. After the complete system has been installed do the

following procedure to make sure the coolant has been
pumped through the system (see NOTE):

NOTE

Depending on the length of the torch leads or-
dered with the system more coolant may need to
be added after turning ON the system for the first
time.

a. Place the ON/OFF Switch to ON.

b. After about 10 seconds the system will shut down

(see NOTE).

NOTE

DO NOT allow the pump to operate for more than
10 seconds the first time the system is turned ON.

c. Place the ON/OFF switch to OFF.

d. After 10 seconds place the ON/OFF switch to

ON again.

e. Repeat steps ‘b’ through ‘d’ until the system no

longer shuts down. Depending on the length of
the torch leads this sequence may need to be done
three to five times.

f. After the system stays operational allow the pump

to operate for ten minutes to properly purge any air
from the coolant lines before using the system.

6. Remove the filler cap, re-fill the reservoir, place the deion-

izer bag into the basket in the coolant reservoir and re-
install the filler cap.

Advertising