Appendix 13: publication history – Tweco 300 Ultra-Cut User Manual
Page 150
Manual 0-4819 Ultra-Cut 300
A-32
APPENDIX
APPENDIX 13: Publication History
Cover Date
Rev.
Change(s)
Nov. 21, 2005
- -
Drafted.
Dec. 9, 2005
- -
Updated gas applications chart; added detail on routing input leads through leads
bracket. Updated Remote Arc Starter schematic from Rev AA to Rev AB. Added
caution against using ohmic sensing with water shield.
Jan. 16, 2006
- -
Updated system layout charts; updated installation and replacement parts illustra
tions for Gas Control Module and Torch Valve Assembly w/ second water line;
updated schematics.
Feb. 20, 2006
- -
Updated torch sections for 30A MS O2/O2 (new chart); 70A SS & AL, new part
numbers and charts; 100A cup installation art; added info on setting pre-charge
pressure for marking; updated schematic for GCM. Added system schematics.
Apr. 25, 2006
AA
In Section 8, updated 30A Aluminum N2/H20 speeds. Added maximum input
gas pressure. Added preflow gases to gas applications chart. Added torch
specifications. Changed ‘F1’ ground wire size from 1/0 to #4. Added note, ‘side
pressure can break check valves/connections to torch valve’. Added error code
group 6, Non-recoverable fault, Contact TDC for resolution’ (CCM software
V2.3.1). Started using new cover styles.
Ref: ECO B-122.
August 25, 2006
AA.01 Added leads lengths C and D as part of ECO B122 missed earlier. Corrected
artpages 2-2, 3-2, 3-3, 6-2 and 6-3 adding callout letters on system layout
diagramsadded G art and removed S art from cables and leads diagram. Removed
referenceand art for Coolant Deionizer Bag and Basket. Inserted GasControl
Modulediagram in Apdx 3. Updated rev. to new version to include numbers.
Oct. 10, 2006
AB.01 Added 400V, 400V CE and 600V inerter module part numbers.
Jan. 10, 2007
AC.01 Updated Error codes in section 4 and added notice to update to Firmware revision
2.4 or later. Updated Gas Control PCB layout in the Appendix.
Mar. 5, 2007
AD.01 Updated with new XTL TVA art and part numbers per ECOB356. Corrected
plasma and shield hose lengths to 4’ with new part numbers. Corrected art in
section 3 showing hookup of work leads, input power etc..
Mar. 13, 2007
AE.01 Corrected Switch settings pgs 3-5, 3-6 and 3-7 for SW8-2.
Mar. 28, 2007
AF.01
Updated the Gas Requirement chart in section 2.
July 10, 2007
AG.01 Added mounting dimensions for GCM, RAS and XTL TVA per ECOB514.
Oct. 15, 2007
AH
Updated pump and motor numbers per ECOB444 in seciton 6.
Oct. 29, 2007
AI
Updated o-ring part number per ECOB467.
Jan. 14, 2008
AJ
Added flow meter parts per ECOB704. Updated schematics per ECOB402
Jan. 28, 2008
AK
Per ECOB738 added GCM plumbing diagram to the Appendix.
Feb. 5, 2008
AL
Per ECOB646 added input terminal strip information to sections 3 and 6.
Apr. 11, 2008
AM
Per ECOB475 updated art for GCM PCB on pg.A-5 and multiple additions and
corrections to sections 3, 4 and 6. Also added pilot transfer retry info switch
setting per ECOB799 pg. 3-16
July 24, 2008
AN
Per ECOB1007 update negative cable connection for the RAS section 3.
Nov. 11, 2008
AO
Updated section 3 per ECOB1163 to show new single shielded leads. Also up
dated some sheetmetal repair parts and Cat number from section 6.
July 16, 2009
AP
Corrected part number for item 13 on page 6-21 to show 9-9407 per ECOB1477.
Sept. 29, 2009
AQ
Updated Appendix with new CNC Functions information and system schematics
with serial communication connector per ECOB1535.