SPECIFICATIONS

2.06 Specifications & Electrical Requirements

Max OCV (U

0

)

380 vdc

Minimum Output Current

10 Amps

Max Output Current

300 Amps

Output Voltage

60 - 230 vdc

Duty Cycle Rating

100% @ 300A, 180V, (54kW),

Ambient Temperature
for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 300 A DC Output

Cooling

Forced Air (Class F)

Ultra-Cut 300 Specifications & Design Features

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

74

206

260

#3/0

230

50/60

72

181

230

#2/0

400 (Incl. CE)

50/60

75

109

135

#3

460

50/60

89

112

150

#2

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

Ultra-Cut 300 Power Supply

2.07 System Component Layout

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-07234

Torch

Coolant Supply

Coolant Return

Control Cable

Coolant Supply

Coolant Return

Plasma Gas

Shield Gas

Fiber
Optic

Cable

Control

Cable

Gas Control

Module

300-A

Power
Supply

Torch

Valve

Assembly

Positioning Tube

Plasma Gas

Preflow Gas

Water Shield

Shield

Shield Gas

Negative Leads

Control Cable

Pilot Return

Pilot Return

Work Cables

Shield

25’ / 7.6 m Maximum Length

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Advertising