10 connect fiber optic cable, 10 connect fiber optic cable -15 – Tweco 300 Ultra-Cut User Manual

Page 39

Advertising
background image

Manual No. 0-4819 Ultra-Cut 300

3-15

INSTALLATION

3.10 Connect Fiber Optic Cable

CAUTION

Check the type of internal control module. Use this section for connections to an internal control
module without an external connections cover. Use the preceding section for connections to an
internal module with an external connections cover.

1. Connect one end of each cable to the power supply as shown.

a. Remove the strain relief securing nut from the strain relief on the fiber optic cable(s). Loosen the strain

relief dome nut from the strain relief.

b. Pass the cable connector through the appropriate opening. Slide the strain relief securing nut onto the

cable. Make a loop of the cable; carefully press the cable connector into the appropriate receptacle on the
internal control module.

c. Tighten the strain relief onto the cable(s). Do not overtighten.

Thin nut securing
the through hole
protector

Fiber Optic
Cable
Plug

Art # A-09456