INSTALLATION

SECTION 3:

INSTALLATION

3.01 Unpacking

The product is packaged and protected to prevent damage during shipping.

1. Unpack each item and remove all packing material.

2. Locate the packing list(s) and use the list to identify and account for each item.

3. Inspect each item for possible shipping damage. If damage is evident, contact your distributor and/or shipping

company before proceeding with system installation.

3.02 Oxygen Plasma Pre-Charge Unit Installation

The Oxygen Plasma Pre-Charge Unit is an addition to the Gas Control console on the HD-3070 Power Supply. The
pre-charge unit is used to increase the line pressure of the plasma gas (Oxygen) at the start of a cut cycle. The pre-
charge unit is activated only during pre-flow when the gas selection switch is set to cut with Oxygen. This added
pressure provides improved consumable life during piercing. When cutting with any other plasma gas, the pre-charge
unit is not activated.

NOTE

The Thermal Dynamics Pre-Charge Unit is for use only with oxygen (O

2

)

gas.

Art # A-06722

Oxygen Plasma Pre-Charge Unit

A. Parts Supplied

The Pre-Charge Unit includes:

Oxygen Plasma Pre-Charge Unit

Oxygen Plasma Pre-Charge Supply Hose

Oxygen Plasma Pre-Charge Outlet Hose

Oxygen Plasma Outlet Tee Assembly

Flashback Arrestor

Advertising