Mild steel 30a o, Plasma / o, N2 shield – Tweco XTTM-300 User Manual
Page 28
Operation with Manual Gas Control
4A-4
Manual 0-2912
Mild Steel
30A
O
2
Plasma / O
2
- N2 Shield
Or
Ar
t # A-06838
Manual
Gas Control
Cartridge
21-1020
Electrode
21-1068
Plasma
Gas Distributor
21-1040
Tip
21-1050
Shield Cap
21-1024
Shield Cup
21-1016
Art # A-04338
Shield
Gas Distributor
21-1082
(ga)
(in)
O
2
-
O
2
N2
O
2
N2
20
0.036
13
-
13
0
5
55
129
0.050
140
0.120
0.2
16
0.060
13
-
13
0
5
55
137
0.050
80
0.120
0.2
14
0.075
13
-
13
0
5
55
139
0.070
50
0.120
0.2
11
0.120
13
-
17
3
5
55
140
0.070
40
0.120
0.2
10
0.135
13
-
17
3
5
55
142
0.070
35
0.120
0.2
9
0.150
13
-
17
3
5
55
143
0.070
33
0.120
0.3
7
0.179
13
-
17
3
5
55
144
0.070
30
0.120
0.3
O
2
-
O
2
N2
O
2
N2
13
-
13
0
5
55
125
1.3
4.8
3.0
0.1
13
-
13
0
5
55
125
1.3
4.1
3.0
0.1
13
-
13
0
5
55
129
1.3
3.6
3.0
0.1
13
-
13
0
5
55
129
1.3
2.9
3.0
0.1
13
-
13
0
5
55
136
1.3
2.2
3.0
0.2
13
-
13
0
5
55
139
1.8
1.3
3.0
0.2
13
-
17
3
5
55
140
1.8
1.1
3.0
0.2
13
-
17
3
5
55
142
1.8
0.9
3.0
0.2
13
-
17
3
5
55
145
1.8
0.7
3.0
0.3
Bold type indicates maximum piercing parameters.
Material
Thickness
Cut Flow Rates (%)
Preflow Flow
Rates
** Arc
Voltage
(volts)
Plasma (%)
Shield (%)
Preflow (%)
Torch
Working
Height
(in)
Travel
Speed
(ipm)
Initial
Piercing
Height
(in)
Pierce
Delay
(sec)
Pierce
Delay
(sec)
Material
Thickness
(mm)
Cut Flow Rates (%)
Preflow Flow
Rates
** Arc
Voltage
(volts)
Plasma (%)
Shield (%)
Preflow (%)
1.2
Torch
Working
Height
(mm)
Travel
Speed
(m/min)
Initial
Piercing
Height
(mm)
0.6
0.8
1
5
1.5
2
3
4